Load Bank

We are a leading Exporter of ac load banks, dc load bank, varicon series load bank and digital data logging volt logger from Mumbai, India.

AC Load Banks

AC Load Banks
  • AC Load Banks
Get Best Quote
Approx. Price: Rs 2 Lakh / Unit(s)
The NEW AC load bank range offer portable single phase 240V load banks which are small, lightweight and low cost. The extended range ratings provides full safety features including contractor isolation and HRC fuse protection and covers from 3kW to 30kW, allow testing for standard single phase UPS systems and generators.

A version of this range is also available at 3phase 220V 60Hz.

  • Simple operation
  • Safety isolation contactors
  • Fan fail protection
  • Low cost
  • High power
  • Cable set included
  • No aux mains required
  • Hrc fuse protection
  • Hand held controller option
  • Power meter option
  • Computer data logging option

The AC series load banks offer a low cost solution to on-site AC testing of small UPS and generators. Units incorporate force cooled high powered, isolated resistor elements plus safety features including HRC fuse protection, isolation contactors and fan failure shut down plus 3 metre cable sets with matching connectors. Optional extras include hand held controller or panel meter with digital display of volts, amps, power and frequency plus data logging to separate laptop computer.
Request
Callback
Yes! I am Interested

DC Load Bank

DC Load Bank
  • DC Load Bank
Get Best Quote
Approx. Price: Rs 2 Lakh / Unit(s)
Automatic multi-voltage dc load bank complete with wireless battery monitoring.

Features:

  • Light weight portable design
  • Automatic operation
  • Wide voltage range
  • Current - power - resistance mode
  • Digital display
  • Wireless battery monitoring
  • Pc software test evaluation
  • Fully adjustable
Request
Callback


Additional Information:

  • Item Code: HCWM-Series
Yes! I am Interested

Varicon Series Load Bank

Varicon Series Load Bank
  • Varicon Series Load Bank
Get Best Quote
Approx. Price: Rs 2 Lakh / Unit(s)
DC load banks offer solutions to meet the budget and technical requirements of all battery discharge testing and are offered from: 12V, 24V, 28V 48V, 60V, 120V, 240V, 440V, 650V, 1000V, & 1200V DC with current ratings up to 4000A.

Features:

  • Automatic range selection
  • Lead Acid or Ni-cad battery testing
  • Automatic constant current control
  • Wide voltage range up to 520V DC
  • Simple operation via hand held controller
  • Auto stop on time and battery voltage
  • Safety isolation contactors
  • Fan fail protection
  • High power up to 28KW
  • Compact design Cables included
  • Portable
  • Computer interface option
Request
Callback
Yes! I am Interested

Digital Data Logging Volt Logger

Digital Data Logging Volt Logger
  • Digital Data Logging Volt Logger
Get Best Quote
Approx. Price: Rs 2 Lakh / Unit(s)
The Voltlogger has been specifically designed for the Battery test & maintenance industry replacing the traditional, potentially inaccurate, 'paper and pencil' methods. The data logging voltmeter automatically measures and records cell voltages in less than 1 second and increments the cell counter ready to read the next cell, enabling the user to take readings from a string of cells without interruption. A new discharge test mode is included for monitoring battery discharge tests, 11 sets of 256 voltage readings. This data can then be downloaded and analysed with the supplied Win-meter Analysis Software, enabling full reports to be printed and stored as well as quickly identifying cells that are out of tolerance and likely to require further maintenance.

System Features & Benefits

  • Measure, time stamp, store voltages in less than 1 second with immediate audio and visual out-of –tolerance indication. See the results on display in

Graphic format.

  • Float Mode; record in either 8 strings of 256 or 20 strings of 48 formats.
  • Discharge Mode; Every cell reading is time stamped, record up to 11 sets of 256 cell voltage data.
  • (Optional) record 256 time stamped Load Current readings (from another instrument not provided)
  • Upload and view CTL-200 Specific Gravity and temperature readings.(Instrument not included)
  • Splash-proof membrane keypad with separate keys for ON/OFF, Recall and Print.


Hardware Specification

  • Communication Interface IRDA infrared, USB.
  • Software Win-meter Windows based programme enables stored data to be analysed, or alternatively exported directly into EXCEL format.
  • Power Requirements Lithium Ion pack (3.7V 2200mAh) with built-in protection chip board (for over charged, over-discharged, short-circuit), Approx 15 Hours service, Auto off after 5 Mins.
  • Display OLED 256 Colour, 35 x 28mm, resolution 160 by 128 pixels
  • Dimensions Instrument only 160 x 80 x 35mm (Approx) With Robust case
  • Specification Input 0-4V 1mV resolution Accuracy +/-5mV, Input 4-20V 1mV resolution Accuracy +/10mV.
  • Environmental Temperature r
Request
Callback
Yes! I am Interested