Call 08048603281 76% Response Rate

Send Email

Power Quality Analyzer

Leading Wholesale Trader of pqm-703 power quality analyzer, pqm-702 power quality analyzer, pqm-711 power quality analyzer, sonel pqm 701z power quality analyzer, stx/ltx transformer monitoring system and themys tma analyzer from Mumbai.
PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer

PQM-703 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-703
Temperature+55 Deg. C
BrandSonel
Battery Life8 Hrs
Nominal Frequency50 Hz
IP RatingIP65
Warranty1 Year

PQM-703 Power Quality Analyzer is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x

In practice, the analyzer may be used with all network types with rated voltage from 110 V to 760 V, directly or indirectly via transducers. It works in the following networks:

  • One-phase,
  • Split-phase with N wire,
  • Three-phase Wye type, with and without N wire,
  • Three-phase delta type,
  • With constant voltage.


Thanks to these features PQM -703 can be used in power engineering and maintenance services fields for industrial plants , as well as by persons providing services in the power network analysis field.

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Mains signaling up to 3000 Hz.
  • Transients up to ±6000 V, minimal transient capturing time is 650 ns.
  • All parameters meet Class A acc. IEC 61000-4-30 standard.
Get Best QuoteRequest A Callback
PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer

PQM-702 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-702
Display TypeLCD
BrandSonel
Battery Life8 Hrs
Warranty1 Year
Frequency70Hz
IP RatingIP65
Lead Legth3 m

Features:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 110V to 690V, with particular emphasis on measurements at low voltage poles, due to the ease of connection.
  • Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.
  • Has a built-in GSM modem.
  • Anti-theft feature - SMS notification in the event of position’s change
Get Best QuoteRequest A Callback
PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer
  • PQM-702 Power Quality Analyzer

PQM-702 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
BrandSonel
Model Name/NumberPQM-702
Display TypeDigital
Frequency50 Hz
Voltage230 V
Power SourceElectric
Features:
  • Power from the measured network
  • Designed for use in virtually all network types from 64 V to 760 V directly, with particular emphasis on measurements at low voltage poles, due to the ease of installation
  • Independent power supply makes it particularly suitable for measurements behind voltage transformers. It can also be used for measurements in DC voltage systems
  • Remote configuration and data transfer in real time using the built-in GSM modem
  • Anti-theft function – text message notification in case of position change – built-in GPS receiver
  • Real time clock synchronized using GPS protocol
Get Best QuoteRequest A Callback
PQM-711 Power Quality Analyzer
  • PQM-711 Power Quality Analyzer
  • PQM-711 Power Quality Analyzer
  • PQM-711 Power Quality Analyzer
  • PQM-711 Power Quality Analyzer

PQM-711 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-711
Frequency50 Hz
Temperature+55 Deg. C
Voltage230 V
BrandSonel
Power SourceElectric
We are offering PQM-711 Power Quality Analyzer to our clients. This product is used for analazing the quaity.
Get Best QuoteRequest A Callback
Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer

Sonel PQM 701Z Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-701Z
Display TypeDigital
BrandSonel
Current with range3 kA
Nominal Frequency50Hz
AC current TRMS0,01 % of Nominal Range
Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits. Analizer Measures And Records According To The En 61000 - 4-30 Class-A Standard.

The device is designed to work with networks with nominal voltage:

  • 110/190 V,
  • 115/200 V,
  • 220/380 V,
  • 230/400 V,
  • 240/415 V,
  • 400/690 V.

The network configuration is set from the computer software.

Supported networks:

  • Single-phase,
  • Two-phase with the common N,
  • Three-phase star with and without N,
  • Three-phase triangle.

 

Possible Measurements:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE (five inputs, compiles with EN 61000 - 4-30, class A)
  • - average, minimum, maximum and instantaneous values, range to 690 V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
  • - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40 Hz to 70 Hz (compiles with EN 61000 - 4-30, class A),
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Power recording:
  • - Budeanu method,
  • - IEEE 1459,
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current (compiles with EN 61000 - 4-7, class I),
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker (compiles with EN 61000 - 4-15, class A),
  • Unballace of Voltage (compiles with EN 61000 - 4-30, class A) and current,
  • Voltage dips, swells and interruption registration including oscillograms (compiles with EN 61000 - 4-30, class A),
  • Current events registration including oscillograms,
  • Current and voltage oscillograms registration after each averaging period.
Get Best QuoteRequest A Callback
STX/LTX Transformer Monitoring System
  • STX/LTX Transformer Monitoring System
  • STX/LTX Transformer Monitoring System
  • STX/LTX Transformer Monitoring System

STX/LTX Transformer Monitoring System

Get Latest Price

Product Brochure

Product Details:
Display TypeDigital
BrandQualitrol
Model Name/NumberSTX Chassis
DC Current Loops20 mA DC
DC Voltage100 mV DC and 10 VDC
Potentiometer15,000 ohms

Qualitrol Bushing Monitor System is an on-line Tanδ (PF) and Capacitance monitoring system for substation bushings. It measures the phase difference induced by capacitive layers of bushings and calculates the rate of change to predict defects in bushing insulation. It can predict defects related to partial breakdowns, moisture, contact problems and aging of insulation material. Bushing monitoring can be done for LV bushing, HV Bushings and both LV and HV bushing togethers.

· Supports 1 to 6 bushings independently.

· 1 Spare/available module to grow with you and your needs (analog signal, digitals)

· Can integrate 3 party devices and other Qualitrol Transformer monitors (DGA, UHF Partial Discharges Systems, Breather, etc)

Get Best QuoteRequest A Callback
Themys TMA Analyzer
  • Themys TMA Analyzer
  • Themys TMA Analyzer
  • Themys TMA Analyzer
  • Themys TMA Analyzer

Themys TMA Analyzer

Get Latest Price

Product Brochure

Product Details:
Usage/ApplicationLaboratory Use
Display TypeDigital
BrandSetaram
Phase3
Technology TypeThermal Analysis
Weight30 kg
Minimum Temperature2400 deg C
PortableBenchtop
Incorporated in the year 2007, we, Om Technical Solutions, have established ourselves amidst the noticeable organizations which are affianced in Wholesale Trading, Exporting and Importing an quality assured array of Thermal Imagers, Power Quality Analyzer, Insulation Monitoring Solutions, Electrical Relays, Digital Multimeter and much more
Get Best QuoteRequest A Callback
DSC TGA TMA Setaram Setline Thermal Analyzer
  • DSC TGA TMA Setaram Setline Thermal Analyzer
  • DSC TGA TMA Setaram Setline Thermal Analyzer
  • DSC TGA TMA Setaram Setline Thermal Analyzer
  • DSC TGA TMA Setaram Setline Thermal Analyzer

DSC TGA TMA Setaram Setline Thermal Analyzer

Get Latest Price

Product Brochure

Product Details:
Frequency50 Hz
Mass Variation range (mg)200 mg
Programmable heating rate50 e ( degree C/min)
Mass variation resolution0.0023 (small range)
Power230 V
Weighing accuracy (%)0.03 %
Gas Flow Range (ml/min)100 ml/min

Setline is easy to use and easy to own. It combines:

• Performing mass measurement, based on the recognized principle of hang-down balances

• A convenient and efficient temperature calibration system

• Compact design, space efficient for all laboratories

• Powerful and intuitive Calisto thermal analysis software

Applications:
Setline brings Setaram’s thermal analysis expertise to education and quality control specialists. It meets the most important needs, from the acquisition of thermal analysis skills through to basic research, and to most Quality Control applications. It characterizes polymers, elastomers, pharmaceuticals, coals, oils, lubricants and many more.

Get Best QuoteRequest A Callback
TGA Setaram Setline Thermal Analyzer
  • TGA Setaram Setline Thermal Analyzer
  • TGA Setaram Setline Thermal Analyzer
  • TGA Setaram Setline Thermal Analyzer

TGA Setaram Setline Thermal Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberSTA Setaram
Usage/ApplicationLaboratory Use
Display TypeDigital
BrandSetaram
Frequency50 Hz
Packaging TypeBox
DSC measurement range (mW)+/- 6 000
BodyPlastic
Autosampler59 positions
Power requirements230V

Setline is easy to use and easy to own. It combines:

• Performing mass measurement, based on the recognized principle of hang-down balances

• A convenient and efficient temperature calibration system

• Compact design, space efficient for all laboratories

• Powerful and intuitive Calisto thermal analysis software


Applications:

Setline brings Setaram’s thermal analysis expertise to education and quality control specialists. It meets the most important needs, from the acquisition of thermal analysis skills through to basic research, and to most Quality Control applications. It characterizes polymers, elastomers, pharmaceuticals, coals, oils, lubricants and many more.

Get Best QuoteRequest A Callback
DSC Differential Scanning Calorimeter
  • DSC Differential Scanning Calorimeter
  • DSC Differential Scanning Calorimeter
  • DSC Differential Scanning Calorimeter

DSC Differential Scanning Calorimeter

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberDSC
BrandSetaram
ColorRed & White
Power230 V
Frequency50 Hz
Power SourceElectric
We are one of the suppliers for Differential Scanning Calorimeter ( DSC )in India, based in Mumbai. 
Get Best QuoteRequest A Callback

EXPLORE MORE CATEGORIES

Contact Us
 
Thank youYour Enquiry has been sent successfully.
© Om Technical Solutions. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.