- Home
- ยป
- Our Products
- »
- Power Quality Analyzer
Power Quality Analyzer
PQM-711 Power Quality Analyzer
Model Name/Number | PQM-711 |
Frequency | 50 Hz |
Temperature | +55 Deg. C |
Voltage | 230 V |
Brand | Sonel |
Power Source | Electric |
TGA Setaram Setline Thermal Analyzer
Product Brochure
Model Name/Number | STA Setaram |
Usage/Application | Laboratory Use |
Display Type | Digital |
Brand | Setaram |
Frequency | 50 Hz |
Packaging Type | Box |
Autosampler | 59 positions |
Power requirements | 230V |
DSC measurement range (mW) | +/- 6 000 |
Body | Plastic |
Setline is easy to use and easy to own. It combines:
• Performing mass measurement, based on the recognized principle of hang-down balances
• A convenient and efficient temperature calibration system
• Compact design, space efficient for all laboratories
• Powerful and intuitive Calisto thermal analysis software
Applications:
Setline brings Setaram’s thermal analysis expertise to education and quality control specialists. It meets the most important needs, from the acquisition of thermal analysis skills through to basic research, and to most Quality Control applications. It characterizes polymers, elastomers, pharmaceuticals, coals, oils, lubricants and many more.
Themys TMA
Product Brochure
Usage/Application | Laboratory Use |
Display Type | Digital |
Brand | Setaram |
Phase | 3 |
Technology Type | Thermal Analysis |
Weight | 30 kg |
Minimum Temperature | 2400 deg C |
Portable | Benchtop |
DSC TGA TMA Setaram Setline Thermal Analyzer
Product Brochure
Frequency | 50 Hz |
Programmable heating rate | 50 e ( degree C/min) |
Gas Flow Range (ml/min) | 100 ml/min |
Mass Variation range (mg) | 200 mg |
Weighing accuracy (%) | 0.03 % |
Mass variation resolution | 0.0023 (small range) |
Power | 230 V |
Setline is easy to use and easy to own. It combines:
• Performing mass measurement, based on the recognized principle of hang-down balances
• A convenient and efficient temperature calibration system
• Compact design, space efficient for all laboratories
• Powerful and intuitive Calisto thermal analysis software
Applications:
Setline brings Setaram’s thermal analysis expertise to education and quality control specialists. It meets the most important needs, from the acquisition of thermal analysis skills through to basic research, and to most Quality Control applications. It characterizes polymers, elastomers, pharmaceuticals, coals, oils, lubricants and many more.
DSC
Product Brochure
Model Name/Number | DSC |
Brand | Setaram |
Color | Red & White |
Power | 230 V |
Frequency | 50 Hz |
Power Source | Electric |
STX Chassis Transformer Monitoring System
Display Type | Digital |
Brand | Qualitrol |
Model Name/Number | STX Chassis |
DC Current Loops | 20 mA DC |
DC Voltage | 100 mV DC and 10 VDC |
Potentiometer | 15,000 ohms |
Qualitrol Bushing Monitor System is an on-line Tanδ (PF) and Capacitance monitoring system for substation bushings. It measures the phase difference induced by capacitive layers of bushings and calculates the rate of change to predict defects in bushing insulation. It can predict defects related to partial breakdowns, moisture, contact problems and aging of insulation material. Bushing monitoring can be done for LV bushing, HV Bushings and both LV and HV bushing togethers.
· Supports 1 to 6 bushings independently.
· 1 Spare/available module to grow with you and your needs (analog signal, digitals)
· Can integrate 3 party devices and other Qualitrol Transformer monitors (DGA, UHF Partial Discharges Systems, Breather, etc)
PQM-703 Power Quality Analyzer
Product Brochure
Model Name/Number | PQM-703 |
Temperature | +55 Deg. C |
Brand | Sonel |
IP Rating | IP65 |
Nominal Frequency | 50 Hz |
Warranty | 1 Year |
Battery Life | 8 Hrs |
PQM-703 Power Quality Analyzer is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x
In practice, the analyzer may be used with all network types with rated voltage from 110 V to 760 V, directly or indirectly via transducers. It works in the following networks:
- One-phase,
- Split-phase with N wire,
- Three-phase Wye type, with and without N wire,
- Three-phase delta type,
- With constant voltage.
Thanks to these features PQM -703 can be used in power engineering and maintenance services fields for industrial plants , as well as by persons providing services in the power network analysis field.
- Measurements according to EN 50160
- Voltage L1, L2, L3, N-PE
- average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs)
- average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40Hz to 70Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- K factor (transformer overload caused by the harmonics),
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current events detection including waveforms recording,
- Current and voltage waveforms recording after each averaging period.
- Mains signaling up to 3000 Hz.
- Transients up to ±6000 V, minimal transient capturing time is 650 ns.
- All parameters meet Class A acc. IEC 61000-4-30 standard.
PQM-702 Power Quality Analyzer
Product Brochure
Model Name/Number | PQM-702 |
Display Type | LCD |
Brand | Sonel |
Battery Life | 8 Hrs |
Warranty | 1 Year |
Frequency | 70Hz |
IP Rating | IP65 |
Lead Legth | 3 m |
Features:
- Measurements according to EN 50160
- Voltage L1, L2, L3, N-PE
- average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs)
- average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40Hz to 70Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- K factor (transformer overload caused by the harmonics),
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current events detection including waveforms recording,
- Current and voltage waveforms recording after each averaging period.
- Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 110V to 690V, with particular emphasis on measurements at low voltage poles, due to the ease of connection.
- Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.
- Has a built-in GSM modem.
- Anti-theft feature - SMS notification in the event of position’s change
Sonel PQM 701Z Power Quality Analyzer
Product Brochure
Model Name/Number | PQM-701Z |
Display Type | Digital |
Brand | Sonel |
Current with range | 3 kA |
Nominal Frequency | 50Hz |
AC current TRMS | 0,01 % of Nominal Range |
The device is designed to work with networks with nominal voltage:
- 110/190 V,
- 115/200 V,
- 220/380 V,
- 230/400 V,
- 240/415 V,
- 400/690 V.
The network configuration is set from the computer software.
Supported networks:
- Single-phase,
- Two-phase with the common N,
- Three-phase star with and without N,
- Three-phase triangle.
Possible Measurements:
- Measurements according to EN 50160
- Voltage L1, L2, L3, N-PE (five inputs, compiles with EN 61000 - 4-30, class A)
- - average, minimum, maximum and instantaneous values, range to 690 V, ability to work with voltage transformers,
- Current L1, L2, L3, N (four inputs)
- - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
- Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz (compiles with EN 61000 - 4-30, class A),
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- - Budeanu method,
- - IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- K factor (transformer overload caused by the harmonics),
- Up to 50th harmonics for voltage and current (compiles with EN 61000 - 4-7, class I),
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker (compiles with EN 61000 - 4-15, class A),
- Unballace of Voltage (compiles with EN 61000 - 4-30, class A) and current,
- Voltage dips, swells and interruption registration including oscillograms (compiles with EN 61000 - 4-30, class A),
- Current events registration including oscillograms,
- Current and voltage oscillograms registration after each averaging period.
PQM-702 Power Quality Analyzer
Product Brochure
Brand | Sonel |
Model Name/Number | PQM-702 |
Display Type | Digital |
Frequency | 50 Hz |
Voltage | 230 V |
Power Source | Electric |
- Power from the measured network
- Designed for use in virtually all network types from 64 V to 760 V directly, with particular emphasis on measurements at low voltage poles, due to the ease of installation
- Independent power supply makes it particularly suitable for measurements behind voltage transformers. It can also be used for measurements in DC voltage systems
- Remote configuration and data transfer in real time using the built-in GSM modem
- Anti-theft function – text message notification in case of position change – built-in GPS receiver
- Real time clock synchronized using GPS protocol