Product Details:
BrandSetaram Kep Technologies
Packaging TypeBox Packing
DeliveryPan India
Warranty1 Year
UsageCement, Rubber, Pharma, FMCG, Nuclear, Polymers, Tyres, Chemicals, Fertilizers and other Industries
ServiceAfter Sales Service Available
Incorporated in the year 2007, we, Om Technical Solutions, have established ourselves amidst the noticeable organizations which are affianced in Wholesale Trading, Exporting and Importing an quality assured array of Thermal Imagers, Power Quality Analyzer, Insulation Monitoring Solutions, Electrical Relays, Digital Multimeter and much more
Get Best QuoteRequest A Callback
Themys TMA
  • Themys TMA
  • Themys TMA
  • Themys TMA
  • Themys TMA

Themys TMA

Get Latest Price

Product Brochure

Product Details:
Portablebenchtop
Phase3
Model Name/NumberSTA Setaram
Usage/ApplicationLaboratory Use
Display TypeDigital
Technology Typethermal analysis
Minimum Temperatureminus to 2400 deg C
Weight30kg
BrandSetaram Kep
Incorporated in the year 2007, we, Om Technical Solutions, have established ourselves amidst the noticeable organizations which are affianced in Wholesale Trading, Exporting and Importing an quality assured array of Thermal Imagers, Power Quality Analyzer, Insulation Monitoring Solutions, Electrical Relays, Digital Multimeter and much more
Get Best QuoteRequest A Callback
Differential Scanning Calorimeter
  • Differential Scanning Calorimeter
  • Differential Scanning Calorimeter
  • Differential Scanning Calorimeter

Differential Scanning Calorimeter

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberSETARAM DSC
BrandSETLINE DSC
Automation GradeDSC
Usage/ApplicationPOLYMERS GLASS METALS PHARMA API
MaterialMETALS POLYMERS GLASS CERAMICS
ColorRED
Power230
We are one of the suppliers for Differential Scanning Calorimeter in India, based in Mumbai. 
Get Best QuoteRequest A Callback
Thermo Gravinetric Analyzer
  • Thermo Gravinetric Analyzer
  • Thermo Gravinetric Analyzer
  • Thermo Gravinetric Analyzer

Thermo Gravinetric Analyzer

Get Latest Price

Product Brochure

Product Details:
Usage/ApplicationLaboratory Use
TemperatureMINUS TO 2000
Voltage230
Display TypeDigital
Model Name/NumberSetaram
BrandSETARAM KEP
Power Requiremnets230V
Packaging TypeCARTON BOX
Power Supply230
We are one of the suppliers for Thermo Gravinetric Analyzer in India, based in Mumbai. We provide Quality Products only. 
Get Best QuoteRequest A Callback
TGA
  • TGA
  • TGA
  • TGA

TGA

Get Latest Price

Product Brochure

Product Details:
Display TypeDigital
BrandSETARAM KEP
Power Requiremnets230V
Phase3
Weight30kg
Model Name/NumberSTA Setaram
Usage/ApplicationLaboratory Use
We are one of the suppliers for Thermo Gravinetric Analyzer in India, based in Mumbai. We provide Quality Products only. 
Get Best QuoteRequest A Callback
DSC
  • DSC
  • DSC
  • DSC

DSC

Get Latest Price

Product Brochure

Product Details:
MaterialMETALS POLYMERS GLASS CERAMICS
ColorRED
Power230
Model Name/NumberSETARAM DSC
BrandSETLINE DSC
Automation GradeDSC
Usage/ApplicationPOLYMERS GLASS METALS PHARMA API
We are one of the suppliers for Differential Scanning Calorimeter ( DSC )in India, based in Mumbai. 
Get Best QuoteRequest A Callback
STA
  • STA
  • STA
  • STA

STA

Get Latest Price

Product Brochure

Product Details:
Display TypeDigital
BrandSETARAM
Minimum Temperatureminus to 2400 deg C
Portablebenchtop
Phase3
Model Name/NumberSETARAM STA
Weight30kg
Usage/ApplicationLaboratory Use
We are one of the suppliers for STA in India, based in Mumbai. 
We supply Globally. 
Get Best QuoteRequest A Callback
PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer

PQM-703 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-703
BrandSonel
Temperature-20 to +55 Deg. C
IP RatingIP65
Nominal Frequency50/60Hz
Nominal Voltage64/110 V; 110/190V; 115/200V; 220/380V; 230/400V; 240/415V; 400/690V.
Warranty1 Year
Battery Life8 Hrs

PQM-703 Power Quality Analyzer is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x

In practice, the analyzer may be used with all network types with rated voltage from 110 V to 760 V, directly or indirectly via transducers. It works in the following networks:

  • One-phase,
  • Split-phase with N wire,
  • Three-phase Wye type, with and without N wire,
  • Three-phase delta type,
  • With constant voltage.


Thanks to these features PQM -703 can be used in power engineering and maintenance services fields for industrial plants , as well as by persons providing services in the power network analysis field.

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Mains signaling up to 3000 Hz.
  • Transients up to ±6000 V, minimal transient capturing time is 650 ns.
  • All parameters meet Class A acc. IEC 61000-4-30 standard.
Get Best QuoteRequest A Callback
PQM-702 Power Quality Analyzer

PQM-702 Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-702
Display TypeLCD
BrandSonel
Battery Life8 Hrs
Warranty1 Year
Frequency40Hz - 70Hz
Voltage Range64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 40
IP RatingIP65
Lead Legth2.2-3 m

Features:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 110V to 690V, with particular emphasis on measurements at low voltage poles, due to the ease of connection.
  • Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.
  • Has a built-in GSM modem.
  • Anti-theft feature - SMS notification in the event of position’s change
Get Best QuoteRequest A Callback
Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer

Sonel PQM 701Z Power Quality Analyzer

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPQM-701Z
BrandSonel
Display TypeDigital
Current with range3 kA
Nominal Frequency50/60 Hz
AC current TRMS0,01 % of Nominal Range
Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits. Analizer Measures And Records According To The En 61000 - 4-30 Class-A Standard.

The device is designed to work with networks with nominal voltage:

  • 110/190 V,
  • 115/200 V,
  • 220/380 V,
  • 230/400 V,
  • 240/415 V,
  • 400/690 V.

The network configuration is set from the computer software.

Supported networks:

  • Single-phase,
  • Two-phase with the common N,
  • Three-phase star with and without N,
  • Three-phase triangle.

 

Possible Measurements:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE (five inputs, compiles with EN 61000 - 4-30, class A)
  • - average, minimum, maximum and instantaneous values, range to 690 V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
  • - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40 Hz to 70 Hz (compiles with EN 61000 - 4-30, class A),
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Power recording:
  • - Budeanu method,
  • - IEEE 1459,
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current (compiles with EN 61000 - 4-7, class I),
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker (compiles with EN 61000 - 4-15, class A),
  • Unballace of Voltage (compiles with EN 61000 - 4-30, class A) and current,
  • Voltage dips, swells and interruption registration including oscillograms (compiles with EN 61000 - 4-30, class A),
  • Current events registration including oscillograms,
  • Current and voltage oscillograms registration after each averaging period.
Get Best QuoteRequest A Callback
Bender PEM575  Power Quality and Energy Measurement

Bender PEM575 Power Quality and Energy Measurement

Get Latest Price

Product Brochure

Product Details:
Model Name/NumberPEM575
BrandBender
Display TypeLED
WeightLess than or equal to 1100 g
Operating Temperature-25 to +55 Deg.C
Rated operational voltageAC 230 V
Rated operational current5 A - 6 A
Rated frequency45 to 65 Hz
Cable LengthUp to 1200 m

The digital universal measuring device PEM575 is suited for measuring and displaying electrical quantities of a public electricity network. The PEM575 is able to perform current, voltage, energy consumption and performance measurements as well as displaying individual current/voltage harmonics for assessment of the power quality. The accuracy of active energy measurements corresponds to class 0.2 S in accordance with the reqirements of DIN EN 62053-22 (VDE 0418 Part 3-22). The current inputs are connected via external .../1 A or .../5 A measuring current transformers.


Features:

  • Accuracy class according to IEC 62053-22: 0.2 S
  • Measured quantities
  • Phase voltages UL1, UL2, UL3 in V
  • Line conductor voltages UL1L2, UL2L3, UL3L1 in V
  • Phase currents I1, I2, I3 in A
  • Neutral current (calculated) I0 in A
  • Neutral current (measured) I4 in A
  • Frequency f in Hz
  • Phase angle for U and I in °
  • Power per phase conductor S in kVA, P in kW, Q in kvar
  • Total power S in kVA, P in kW, Q in kvar
  • Displacement factor cos (φ)
  • Power factor λ
  • Active and reactive energy import in kWh, kvarh
  • Active and reactive energy export in kWh, kvarh
  • Voltage unbalance in %
  • Current unbalance in %
  • Harmonic distortion (THD) for U and I
  • k-Factor for I
  • Programmable setpoint monitoring
  • LED pulse outputs for active and reactive energy
  • Modbus/RTU and Modbus/TCP
  • 3 digital outputs
  • Requirements of energy and current for
  • particular time frames
  • Peak demands with timestamps
  • Individual, current/voltage harmonics up to the 63rd harmonic
  • Minimum and maximum values
  • Waveform recording (12.8 kHz)
  • Data recorder
  • Sag/swell detection
  • High-resolution waveform recording
  • Detection of transient events
Typical applicationTypical applicationTypical Application:
  • As a compact device for front panel mounting, the PEM575 is a replacement for analogue indicating instruments•
  • Typical application in low and medium-voltage networks (via measuring voltage transformer)•
  • Power quality monitoring
  • Collection of relevant data for energy management
  • Cost allocation of energy consumption
  • High-resolution waveform recording allow analysis of power quality phenomena.
Description of function Description of function:
  • Sampling rate of the measuring channels: 12.8 kHz
  • Calculation of the total harmonic distortion THDU/THDI: harmonics up to the 63rd harmonic
  • Individual current/voltage harmonics
  • Password protection
  • Clamp mechanism, no tools required
  • History memory for minimum and maximum values of current, voltage, energy, power rating etc. for each month
  • Inputs and outputs: –3 digital outputs, 6 digital inputs, 16 user-programmable setpoints (response values, response delay 0...9999 seconds), System protocol: 512 events, setup changes, setpoint alarming, DI status changes,  DO switching operations
  • Communication: Galvanically isolated RS-485 interface (1,200 bis 19,200 bit/s), Modbus, RTU protocol, Modbus TCP (10/100 Mbit/
Get Best QuoteRequest A Callback
Three Phase Power Quality Meter
  • Three Phase Power Quality Meter
  • Three Phase Power Quality Meter

Three Phase Power Quality Meter

Get Latest Price

Product Details:
Qualitystandard
Featurestandard
We are one of the manufacturers for Three Phase Power Analyzer in India, based in Mumbai. 
Get Best QuoteRequest A Callback
Mechanical Thermal Analysis
  • Mechanical Thermal Analysis
  • Mechanical Thermal Analysis
  • Mechanical Thermal Analysis

Mechanical Thermal Analysis

Get Latest Price

Product Brochure

Product Details:
Product TypeSETARAM
Testing TypeMETALS CERAMICS GLASS
Type Of Test LiquidANY
Any Specific Test CriteriaALL
Application AreaMETALS POLYMERS GLASS CERAMICS
Metal To Be AnalysedMETALS, POLYMERS, CERAMICS , GLASS
Test LocationMUMBAI
Amount Of SampleMG TO G
Analysis TypeTMA
We are one of the suppliers for Mechanical Thermal Analysis in India, based in Mumbai. We provide Quality Products only. 
Get Best QuoteRequest A Callback
Energy Management System

Energy Management System

Get Latest Price

Electro Industries/GaugeTech (EIG) announces the release of its EnergyPQA.com™ next generation Energy Management Cloud solution. This new software system improves the results of energy management systems by adding predictive artificial intelligence and power quality analytics. The system predicts usage trends into the future allowing users to proactively reduce demand and save on energy costs. It also provides deep insights into power quality to increase enterprise power reliability.