Send Email
Send SMS
Search


Power Quality Analyzer

Leading Wholesale Trader of pqm-703 power quality analyzer, pqm-702 power quality analyzer, sonel pqm 701z power quality analyzer and bender pem575 power quality and energy measurement from Mumbai.

PQM-703 Power Quality Analyzer

REQUEST CALLBACK

PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
  • PQM-703 Power Quality Analyzer
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Model Name/NumberPQM-703
BrandSonel
Temperature-20 to +55 Deg. C
IP RatingIP65
Nominal Frequency50/60Hz
Nominal Voltage64/110 V; 110/190V; 115/200V; 220/380V; 230/400V; 240/415V; 400/690V.
Warranty1 Year
Battery Life8 Hrs

PQM-703 Power Quality Analyzer is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x

In practice, the analyzer may be used with all network types with rated voltage from 110 V to 760 V, directly or indirectly via transducers. It works in the following networks:

  • One-phase,
  • Split-phase with N wire,
  • Three-phase Wye type, with and without N wire,
  • Three-phase delta type,
  • With constant voltage.


Thanks to these features PQM -703 can be used in power engineering and maintenance services fields for industrial plants , as well as by persons providing services in the power network analysis field.

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Mains signaling up to 3000 Hz.
  • Transients up to ±6000 V, minimal transient capturing time is 650 ns.
  • All parameters meet Class A acc. IEC 61000-4-30 standard.
Yes! I am Interested

View PDF

PQM-702 Power Quality Analyzer

REQUEST CALLBACK

PQM-702 Power Quality Analyzer
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Model Name/NumberPQM-702
Display TypeLCD
BrandSonel
Battery Life8 Hrs
Warranty1 Year
Frequency40Hz - 70Hz
Voltage Range64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 40
IP RatingIP65
Lead Legth2.2-3 m

Features:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE
    - average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
    - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40Hz to 70Hz ,
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current,
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker,
  • Unbalance of voltage and current,
  • Current events detection including waveforms recording,
  • Current and voltage waveforms recording after each averaging period.
  • Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 110V to 690V, with particular emphasis on measurements at low voltage poles, due to the ease of connection.
  • Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.
  • Has a built-in GSM modem.
  • Anti-theft feature - SMS notification in the event of position’s change
Yes! I am Interested

View PDF

Sonel PQM 701Z Power Quality Analyzer

REQUEST CALLBACK

Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer
  • Sonel PQM 701Z Power Quality Analyzer
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Model Name/NumberPQM-701Z
BrandSonel
Display TypeDigital
Current with range3 kA
Nominal Frequency50/60 Hz
AC current TRMS0,01 % of Nominal Range

Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits. Analizer Measures And Records According To The En 61000 - 4-30 Class-A Standard.

The device is designed to work with networks with nominal voltage:

  • 110/190 V,
  • 115/200 V,
  • 220/380 V,
  • 230/400 V,
  • 240/415 V,
  • 400/690 V.

The network configuration is set from the computer software.

Supported networks:

  • Single-phase,
  • Two-phase with the common N,
  • Three-phase star with and without N,
  • Three-phase triangle.

 

Possible Measurements:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE (five inputs, compiles with EN 61000 - 4-30, class A)
  • - average, minimum, maximum and instantaneous values, range to 690 V, ability to work with voltage transformers,
  • Current L1, L2, L3, N (four inputs)
  • - average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
  • Crest factor for voltage and current,
  • Frequency from 40 Hz to 70 Hz (compiles with EN 61000 - 4-30, class A),
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
  • Power recording:
  • - Budeanu method,
  • - IEEE 1459,
  • Active, reactive, apparent energy,
  • Power factor, cosφ, tgφ,
  • K factor (transformer overload caused by the harmonics),
  • Up to 50th harmonics for voltage and current (compiles with EN 61000 - 4-7, class I),
  • Total Harmonic Distortion (THD) for voltage and current,
  • Short-term (PST) and long-term (PLT) flicker (compiles with EN 61000 - 4-15, class A),
  • Unballace of Voltage (compiles with EN 61000 - 4-30, class A) and current,
  • Voltage dips, swells and interruption registration including oscillograms (compiles with EN 61000 - 4-30, class A),
  • Current events registration including oscillograms,
  • Current and voltage oscillograms registration after each averaging period.
Yes! I am Interested

View PDF

Bender PEM575 Power Quality and Energy Measurement

REQUEST CALLBACK

Bender PEM575  Power Quality and Energy Measurement
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Model Name/NumberPEM575
BrandBender
Display TypeLED
WeightLess than or equal to 1100 g
Operating Temperature-25 to +55 Deg.C
Rated operational voltageAC 230 V
Rated operational current5 A - 6 A
Rated frequency45 to 65 Hz
Cable LengthUp to 1200 m

The digital universal measuring device PEM575 is suited for measuring and displaying electrical quantities of a public electricity network. The PEM575 is able to perform current, voltage, energy consumption and performance measurements as well as displaying individual current/voltage harmonics for assessment of the power quality. The accuracy of active energy measurements corresponds to class 0.2 S in accordance with the reqirements of DIN EN 62053-22 (VDE 0418 Part 3-22). The current inputs are connected via external .../1 A or .../5 A measuring current transformers.


Features:

  • Accuracy class according to IEC 62053-22: 0.2 S
  • Measured quantities
  • Phase voltages UL1, UL2, UL3 in V
  • Line conductor voltages UL1L2, UL2L3, UL3L1 in V
  • Phase currents I1, I2, I3 in A
  • Neutral current (calculated) I0 in A
  • Neutral current (measured) I4 in A
  • Frequency f in Hz
  • Phase angle for U and I in °
  • Power per phase conductor S in kVA, P in kW, Q in kvar
  • Total power S in kVA, P in kW, Q in kvar
  • Displacement factor cos (φ)
  • Power factor λ
  • Active and reactive energy import in kWh, kvarh
  • Active and reactive energy export in kWh, kvarh
  • Voltage unbalance in %
  • Current unbalance in %
  • Harmonic distortion (THD) for U and I
  • k-Factor for I
  • Programmable setpoint monitoring
  • LED pulse outputs for active and reactive energy
  • Modbus/RTU and Modbus/TCP
  • 3 digital outputs
  • Requirements of energy and current for
  • particular time frames
  • Peak demands with timestamps
  • Individual, current/voltage harmonics up to the 63rd harmonic
  • Minimum and maximum values
  • Waveform recording (12.8 kHz)
  • Data recorder
  • Sag/swell detection
  • High-resolution waveform recording
  • Detection of transient events
Typical applicationTypical applicationTypical Application:
  • As a compact device for front panel mounting, the PEM575 is a replacement for analogue indicating instruments•
  • Typical application in low and medium-voltage networks (via measuring voltage transformer)•
  • Power quality monitoring
  • Collection of relevant data for energy management
  • Cost allocation of energy consumption
  • High-resolution waveform recording allow analysis of power quality phenomena.
Description of function Description of function:
  • Sampling rate of the measuring channels: 12.8 kHz
  • Calculation of the total harmonic distortion THDU/THDI: harmonics up to the 63rd harmonic
  • Individual current/voltage harmonics
  • Password protection
  • Clamp mechanism, no tools required
  • History memory for minimum and maximum values of current, voltage, energy, power rating etc. for each month
  • Inputs and outputs: –3 digital outputs, 6 digital inputs, 16 user-programmable setpoints (response values, response delay 0...9999 seconds), System protocol: 512 events, setup changes, setpoint alarming, DI status changes,  DO switching operations
  • Communication: Galvanically isolated RS-485 interface (1,200 bis 19,200 bit/s), Modbus, RTU protocol, Modbus TCP (10/100 Mbit/
Yes! I am Interested

View PDF
 
X


Explore More Products

Contact via E-mail
Contact via SMS
Om Technical Solutions
Timir Doshi (Proprietor)
308, Devraj Mall, Opposite Madhuram Hall Hari Shankar Joshi Marg, Dahisar East,
Mumbai - 400068, Maharashtra, India
Call Us: 
Call Response Rate: 85%
Share Us :
F G T L



Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

© Om Technical Solutions. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited